China Commercial 500LPH RO Water Filter System For Water Treatment Pure Water Make

Brand Name : HYJB

Model Number : 0.5 tons single-stage

Place of Origin : Zhengzhou ,China

MOQ : 1 set

Price : negotiable

Payment Terms : L/C, D/A, D/P, T/T, T/T, Western Union, MoneyGram

Supply Ability : 200 sets /month

Delivery Time : 7 days

Packaging Details : wooden case

Material : PVC

Condition : New

Weight : 250KG

Core Components : Pump, Engine

Qualtity of Tank : Three

Video Outgoing-inspection : Provided

Contact Now

China Commercial 500LPH RO Water Filter System For Water Treatment Pure Water Make

Product Description

The core component of a reverse osmosis water purifier is the reverse osmosis membrane, which is a membrane made of a special material with a very small pore size. When the water purifier starts, the feed pump will send the tap water into the reverse osmosis membrane area, which includes the reverse osmosis membrane and some other membranes, which are used to remove odor, taste, pigment, particles and hardness, etc., and protect the service life of the reverse osmosis membrane. Under the action of the high-pressure pump, the water enters the RO membrane, in the RO membrane is filtered by the reverse osmosis process to remove inorganic salts in the water, impurities, bacteria, etc. The role of the RO membrane is to enter the RO membrane of the water from the different directions of the separation out of the water, in which the high concentration of water that does not need to be filtered out of the water, the low concentration, the need for reverse osmosis of the water will be filtered through the RO membrane to become a safe and clean drinking water that we drink.

Parameter Table

Model
Water Making Ability
Inlet Caliber
Effluent Caliber
Blowdown alCer
Size(mm)
Power
YSRO-0.5T
0.5m3/h
DN20
DN20
DN15
1500×600×1500
1.3kw
YSRO-1T
1m3/h
DN25
DN25
DN20
1700×600×1500
2.1kw
YSRO-2T
2m3/h
DN32
DN25
DN20
2500×1000×1950
4.4kw
YSRO-3T
3m3/h
DN40
DN32
DN25
2500×1200×2150
4.5kw
YSRO-5T
5m3/h
DN50
DN40
DN32
2500×1350×2150
7.0kw
YSRO-8T
8m3/h
DN50
DN50
DN40
3500×1500×2150
11kw
YSRO-10T
10m3/h
DN50
DN50
DN40
3500×1600×2300
15kw

Key Advantage

1. High processing efficiency
Single stage reverse osmosis design, fully utilizing water pressure potential energy to improve water treatment efficiency. The equipment produces a large amount of water per unit time, meeting the demand for rapid water use.
2. High effluent quality
By using high-precision reverse osmosis membrane filtration, soluble salts, organic matter, heavy metal ions, etc. in water are effectively removed, ensuring that the effluent quality meets high standard requirements.
3. Low operating costs
The equipment adopts energy-saving design to reduce energy consumption and operating costs. At the same time, the reverse osmosis membrane has a long lifespan, a long replacement cycle, and reduces maintenance costs.

Maintenance

Regular cleaning: Use special cleaning agents to clean the equipment regularly to remove scale, bacteria and algae and other dirt, and restore the performance of the equipment. Cleaning cycle should be determined according to the water quality and equipment operation time, usually recommended once a quarter.
Filter element and membrane element replacement: regularly check the status of the filter element and membrane element, once found to be worn or performance decline, should be replaced immediately. The replacement cycle varies depending on the equipment model and use environment, but it is usually recommended to replace them at least once a year.
Electrical part inspection: Including motor, control board and other parts, check whether the wiring is loose, whether the electrical components are aging and need to be replaced. At the same time, ensure that the equipment is grounded safely to prevent personal injury and equipment damage caused by electrical failure.
Long-term shutdown maintenance: If the system is shut down for a long period of time, use sterilizing liquid to fill the reverse osmosis system, close the relevant valves and ensure that the sterilizing liquid is completely filled. Long-term shutdown reply before use, be sure to rinse the sterilization fluid.

Product Display

China Commercial 500LPH RO Water Filter System For Water Treatment Pure Water MakeChina Commercial 500LPH RO Water Filter System For Water Treatment Pure Water MakeChina Commercial 500LPH RO Water Filter System For Water Treatment Pure Water MakeChina Commercial 500LPH RO Water Filter System For Water Treatment Pure Water Make


Product Tags:

Commercial RO Water Filter System

      

500LPH RO Water Filter System

      
Wholesale China Commercial 500LPH RO Water Filter System For Water Treatment Pure Water Make from china suppliers

China Commercial 500LPH RO Water Filter System For Water Treatment Pure Water Make Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Jingte 'er Environmental Protection Engineering Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)